MARC details
000 -LEADER |
fixed length control field |
03873nam a22005297a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
2401116s20232023 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1941-7640 |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1161/CIRCINTERVENTIONS.123.013238 [doi] |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
PMC10653288 [pmc] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
37988439 |
245 ## - TITLE STATEMENT |
Title |
Feasibility of Coronary Access Following Redo-TAVR for Evolut Failure: A Computed Tomography Simulation Study. |
251 ## - Source |
Source |
Circulation: Cardiovascular Interventions. 16(11):e013238, 2023 Nov. |
252 ## - Abbreviated Source |
Abbreviated source |
Circ., Cardiovasc. interv.. 16(11):e013238, 2023 Nov. |
253 ## - Journal Name |
Journal name |
Circulation. Cardiovascular interventions |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2023 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2024 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Publication date |
2023 Nov |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
ppublish |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Medline status |
PubMed-not-MEDLINE |
266 ## - Date added to catalog |
Date added to catalog |
2024-01-16 |
520 ## - SUMMARY, ETC. |
Abstract |
BACKGROUND: Coronary accessibility following redo-transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. |
520 ## - SUMMARY, ETC. |
Abstract |
REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02701283. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 (P<0.001). Coronary accessibility improved with a 5-mm Evolut implant depth: 97% at node 4 and 65% at node 5 (P<0.001). When comparing 3- to 5-mm Evolut implant depth, sinus sequestration was the lowest with Sapien-3 outflow at Evolut node 4 (13% versus 2%; P<0.001), and the highest at Evolut node 5 (61% versus 32%; P<0.001). |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Aortic Valve Stenosis |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Heart Valve Prosthesis |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Transcatheter Aortic Valve Replacement |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aortic Valve Stenosis/su [Surgery] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aortic Valve/dg [Diagnostic Imaging] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aortic Valve/su [Surgery] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Feasibility Studies |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Prosthesis Design |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Tomography, X-Ray Computed |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Transcatheter Aortic Valve Replacement/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Treatment Outcome |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Heart & Vascular Institute |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Rogers, Toby |
Institution Code |
MHVI |
790 ## - Authors |
All authors |
Tang GHL, Spencer J, Rogers T, Grubb KJ, Gleason P, Gada H, Mahoney P, Dauerman HL, Forrest JK, Reardon MJ, Blanke P, Leipsic JA, Abdel-Wahab M, Attizzani GF, Puri R, Caskey M, Chung CJ, Chen YH, Dudek D, Allen KB, Chhatriwalla AK, Htun WW, Blackman DJ, Tarantini G, Zhingre Sanchez J, Schwartz G, Popma JJ, Sathananthan J |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1161/CIRCINTERVENTIONS.123.013238">https://dx.doi.org/10.1161/CIRCINTERVENTIONS.123.013238</a> |
858 ## - ORCID |
ORCID text |
Rogers, Toby |
Orcid |
<a href="https://orcid.org/0000-0002-6043-3137">https://orcid.org/0000-0002-6043-3137</a> |
Name |
https://orcid.org/0000-0002-6043-3137 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |