MARC details
000 -LEADER |
fixed length control field |
03959nam a22005177a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
160715s20162016 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
0009-7322 |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
26762519 |
245 ## - TITLE STATEMENT |
Title |
Mechanisms of Very Late Drug-Eluting Stent Thrombosis Assessed by Optical Coherence Tomography. |
251 ## - Source |
Source |
Circulation. 133(7):650-60, 2016 Feb 16. |
252 ## - Abbreviated Source |
Abbreviated source |
Circulation. 133(7):650-60, 2016 Feb 16. |
253 ## - Journal Name |
Journal name |
Circulation |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2016 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2016 |
266 ## - Date added to catalog |
Date added to catalog |
2016-07-15 |
501 ## - WITH NOTE |
Local holdings |
Available online from MWHC library: 1950 - present, Available in print through MWHC library: 1999 - 2006 |
520 ## - SUMMARY, ETC. |
Abstract |
BACKGROUND: The pathomechanisms underlying very late stent thrombosis (VLST) after implantation of drug-eluting stents (DES) are incompletely understood. Using optical coherence tomography, we investigated potential causes of this adverse event. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSIONS: The leading associated findings in VLST patients in descending order were malapposition, neoatherosclerosis, uncovered struts, and stent underexpansion without differences between patients treated with early- and new-generation drug-eluting stents. The longitudinal extension of malapposed and uncovered stent was the most important correlate of thrombus formation in VLST.Copyright © 2016 American Heart Association, Inc. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS AND RESULTS: Between August 2010 and December 2014, 64 patients were investigated at the time point of VLST as part of an international optical coherence tomography registry. Optical coherence tomography pullbacks were performed after restoration of flow and analyzed at 0.4 mm. A total of 38 early- and 20 newer-generation drug-eluting stents were suitable for analysis. VLST occurred at a median of 4.7 years (interquartile range, 3.1-7.5 years). An underlying putative cause by optical coherence tomography was identified in 98% of cases. The most frequent findings were strut malapposition (34.5%), neoatherosclerosis (27.6%), uncovered struts (12.1%), and stent underexpansion (6.9%). Uncovered and malapposed struts were more frequent in thrombosed compared with nonthrombosed regions (ratio of percentages, 8.26; 95% confidence interval, 6.82-10.04; P<0.001 and 13.03; 95% confidence interval, 10.13-16.93; P<0.001, respectively). The maximal length of malapposed or uncovered struts (3.40 mm; 95% confidence interval, 2.55-4.25; versus 1.29 mm; 95% confidence interval, 0.81-1.77; P<0.001), but not the maximal or average axial malapposition distance, was greater in thrombosed compared with nonthrombosed segments. The associations of both uncovered and malapposed struts with thrombus were consistent among early- and newer-generation drug-eluting stents. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Coronary Vessels/pa [Pathology] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Drug-Eluting Stents/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Drug-Eluting Stents/td [Trends] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Thrombosis/di [Diagnosis] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Thrombosis/et [Etiology] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Tomography, Optical Coherence/mt [Methods] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Aged |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Coronary Vessels/su [Surgery] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Cross-Sectional Studies |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Drug-Eluting Stents/st [Standards] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Female |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Male |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Middle Aged |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Prosthesis Failure |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Time Factors |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Heart & Vascular Institute |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Observational Study |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Research Support, Non-U.S. Gov't |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Garcia-Garcia, Hector M |
790 ## - Authors |
All authors |
Abildgaard U, Amabile N, Caussin C, Cook S, Garcia-Garcia HM, Jorgensen E, Juni P, Kelbaek H, Koskinas KC, Pilgrim T, Raber L, Radu MD, Taniwaki M, Veugeois A, Windecker S, Yamaji K, Zanchin T, Zaugg S |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="http://dx.doi.org/10.1161/CIRCULATIONAHA.115.019071">http://dx.doi.org/10.1161/CIRCULATIONAHA.115.019071</a> |
Public note |
http://dx.doi.org/10.1161/CIRCULATIONAHA.115.019071 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |