Placement of a cervical collar increases the optic nerve sheath diameter in healthy adults. (Record no. 2676)

MARC details
000 -LEADER
fixed length control field 03186nam a22004697a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170918s20172017 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 0735-6757
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 28865838
245 ## - TITLE STATEMENT
Title Placement of a cervical collar increases the optic nerve sheath diameter in healthy adults.
251 ## - Source
Source American Journal of Emergency Medicine. 36(3):430-434, 2018 Mar.
252 ## - Abbreviated Source
Abbreviated source Am J Emerg Med. 36(3):430-434, 2018 Mar.
252 ## - Abbreviated Source
Former abbreviated source Replace Date, check full-text
253 ## - Journal Name
Journal name The American journal of emergency medicine
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2018
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2018
266 ## - Date added to catalog
Date added to catalog 2017-09-18
501 ## - WITH NOTE
Local holdings Available online from MWHC library: 1995 - present, Available in print through MWHC library: 1999 - 2006
520 ## - SUMMARY, ETC.
Abstract CONCLUSION: The placement of a cervical collar increased the ONSD at 5min and this change remained increased at 20min. Future study should assess whether similar results are found in patients with blunt head trauma. Copyright (c) 2017. Published by Elsevier Inc.
520 ## - SUMMARY, ETC.
Abstract INTRODUCTION: Blunt head trauma is a common cause of increased intracranial pressure (ICP). Ultrasound measurement of the optic nerve sheath diameter (OSND) is an accurate and non-invasive way to detect increased ICP. Blunt trauma patients are often immobilized in a rigid cervical spine collar. Our objective was to describe the changes in ONSD following the placement of a c-collar and determine if any changes were time-dependent.
520 ## - SUMMARY, ETC.
Abstract METHODS: We performed a prospective cohort study measuring the ONSD of healthy volunteers before and after placement of a c-collar. Two physicians obtained the measurements. Each eye was scanned twice using a standardized technique. This was done before c-collar placement, 5min after placement and 20min after placement. A mean of both eyes was calculated and analyzed using descriptive statistics. An intraclass correlation coefficient (ICC) was used to assess inter-rater reliability.
520 ## - SUMMARY, ETC.
Abstract RESULTS: Twenty study participants with a mean age of 37.1years old were enrolled. The mean baseline ONSD was 3.77mm (95% CI 3.48-4.07). The mean ONSD 5 min after the c-collar was placed was 4.47 (95% CI 4.17-4.78). The mean ONSD at 20min after c-collar placement was 4.53 (95% CI 4.13-4.92). These changes were statistically significant (p=0.003 and <0.001). Reliability was relatively strong overall (ICC=0.74; 95% CI: 0.65, 0.81).
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Braces/ae [Adverse Effects]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Neck
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Optic Nerve/ah [Anatomy & Histology]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Adult
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Female
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Male
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Middle Aged
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Optic Nerve/dg [Diagnostic Imaging]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Prospective Studies
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Ultrasonography
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Washington Hospital Center
656 ## - INDEX TERM--OCCUPATION
Department Emergency Medicine
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Motalib, Sakib
790 ## - Authors
All authors Anderson JP, Greupner JT, Motalib S, Pasquarella JR, Wewerka SS, Woster CM, Zwank MD
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1016/j.ajem.2017.08.051">https://dx.doi.org/10.1016/j.ajem.2017.08.051</a>
Public note https://dx.doi.org/10.1016/j.ajem.2017.08.051
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 09/18/2017   28865838 28865838 09/18/2017 09/18/2017 Journal Article

Powered by Koha