Looking for Holes in Sterile Wrapping: How Accurate Are We?. (Record no. 3066)

MARC details
000 -LEADER
fixed length control field 03336nam a22005057a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180220s20182018 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 0009-921X
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.1007/s11999.0000000000000185 [doi]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 29432266
245 ## - TITLE STATEMENT
Title Looking for Holes in Sterile Wrapping: How Accurate Are We?.
251 ## - Source
Source Clinical Orthopaedics & Related Research. 476(5):1076-1080, 2018 05.
252 ## - Abbreviated Source
Abbreviated source Clin Orthop. 476(5):1076-1080, 2018 05.
253 ## - Journal Name
Journal name Clinical orthopaedics and related research
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2018
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2018
266 ## - Date added to catalog
Date added to catalog 2018-02-20
520 ## - SUMMARY, ETC.
Abstract BACKGROUND: Defects in sterile surgical wrapping are identified by the presence of holes through which light can be seen. However, it is unknown how reliably the human eye can detect these defects.
520 ## - SUMMARY, ETC.
Abstract CONCLUSIONS: Defects <= 2 mm were not reliably detected with respect to lighting, time, or level of experience. Future research is warranted to determine defect sizes that are clinically meaningful.
520 ## - SUMMARY, ETC.
Abstract LEVEL OF EVIDENCE: Level II, diagnostic study.
520 ## - SUMMARY, ETC.
Abstract METHODS: Thirty participants (10 surgical technicians, 13 operating room nurses, seven orthopaedic surgery residents) inspected sterile sheets for perforations under ambient operating room (OR) lighting and then again with a standard powered OR lamp in addition to ambient lighting. There were no additional criteria for eligibility other than willingness to participate. Each sheet contained one of nine defect sizes with four sheets allocated to each defect size. Ten wraps were controls with no defects. Participants were allowed as much time as necessary for inspection.
520 ## - SUMMARY, ETC.
Abstract QUESTIONS/PURPOSES: The purpose of this study was to determine (1) how often holes in sterile packaging of various sizes could be detected; and (2) whether differences in lighting, experience level of the observer, or time spent inspecting the packaging were associated with improved likelihood of detection of holes in sterile packaging.
520 ## - SUMMARY, ETC.
Abstract RESULTS: Holes >= 2.5 mm were detected more often than holes <= 2 mm (87% [832 of 960] versus 7% [82 of 1200]; odds ratio, 88.6 [95% confidence interval, 66.2-118.6]; p < 0.001). There was no difference in detection accuracy between OR lamp and ambient lightning nor experience level. There was no correlation between inspection time and detection accuracy.
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Equipment Contamination/pc [Prevention & Control]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Lighting
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Product Packaging
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Sterilization/mt [Methods]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Surgical Equipment
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Visual Perception
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Internship and Residency
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Nursing Staff, Hospital
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Observer Variation
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Operating Room Technicians
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Operating Rooms
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Orthopedic Surgeons/ed [Education]
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Harbor Hospital
656 ## - INDEX TERM--OCCUPATION
Department Department of Medicine
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Richardson, Mark W
790 ## - Authors
All authors Bush CM, DiPasquale TG, Mayassi HA, Muccino PM, Opalacz BM, Rashidifard CH, Richardson MW
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1007/s11999.0000000000000185">https://dx.doi.org/10.1007/s11999.0000000000000185</a>
Public note https://dx.doi.org/10.1007/s11999.0000000000000185
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 02/20/2018   29432266 29432266 02/20/2018 02/20/2018 Journal Article

Powered by Koha