Optimizing usability and signal capture: a proactive risk assessment for the implementation of a wireless vital sign monitoring system. (Record no. 3560)

MARC details
000 -LEADER
fixed length control field 02732nam a22003617a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171017s20172017 xxu||||| |||| 00| 0 eng d
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER
International Standard Serial Number 0309-1902
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 29027496
245 ## - TITLE STATEMENT
Title Optimizing usability and signal capture: a proactive risk assessment for the implementation of a wireless vital sign monitoring system.
251 ## - Source
Source Journal of Medical Engineering & Technology. 41(8):623-629, 2017 Nov.
252 ## - Abbreviated Source
Abbreviated source J Med Eng Technol. 41(8):623-629, 2017 Nov.
252 ## - Abbreviated Source
Former abbreviated source J Med Eng Technol. :1-7, 2017 Oct 13
253 ## - Journal Name
Journal name Journal of medical engineering & technology
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2017
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2018
266 ## - Date added to catalog
Date added to catalog 2017-10-17
268 ## - Previous citation
-- Journal of Medical Engineering & Technology. :1-7, 2017 Oct 13
520 ## - SUMMARY, ETC.
Abstract Wearable vital sign monitors are a promising step towards optimal patient surveillance, providing continuous data to allow for early detection and treatment of patient deterioration. However, as wearable monitors become more widely adopted in healthcare, there is a corresponding need to carefully design the implementation of these tools to promote their integration into clinical workflows and defend against potential misuse and patient harm. Prior to the roll-out of these monitors, our multidisciplinary team of clinicians, clinical engineers, information technologists and research investigators conducted a modified Healthcare Failure Mode and Effect Analysis (HFMEA), a proactive evaluation of potential problems which could be encountered in the use of a wireless vital signs monitoring system. This evaluation was accomplished by focussing on the identification of procedures and actions that would be required during the devices' regular usage, as well as the implementation of the system as a comprehensive process. Using this method, the team identified challenges that would arise throughout the lifecycle of the device and developed recommendations to address them. This proactive risk assessment can guide the implementation of wearable patient monitors, optimising the use of innovative health information technology.
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Monitoring, Physiologic/mt [Methods]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Risk Assessment/mt [Methods]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Vital Signs/ph [Physiology]
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Institute for Innovation
656 ## - INDEX TERM--OCCUPATION
Department National Center for Human Factors in Healthcare
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Miller, Kristen
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Mosby, Danielle
790 ## - Authors
All authors Arnold R, Capan M, Kowalski R, Lodato P, Miller K, Mosby D, Thomas T
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1080/03091902.2017.1382589">https://dx.doi.org/10.1080/03091902.2017.1382589</a>
Public note https://dx.doi.org/10.1080/03091902.2017.1382589
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 10/17/2017   29027496 29027496 10/17/2017 10/17/2017 Journal Article

Powered by Koha