MARC details
000 -LEADER |
fixed length control field |
02599nam a22003497a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
220511s20222022 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1522-1946 |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1002/ccd.30174 [doi] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
35366386 |
245 ## - TITLE STATEMENT |
Title |
Angiography-derived versus invasively-determined index of microcirculatory resistance in the assessment of coronary microcirculation: A systematic review and meta-analysis. |
251 ## - Source |
Source |
Catheterization & Cardiovascular Interventions. 2022 Apr 02 |
252 ## - Abbreviated Source |
Abbreviated source |
Catheter Cardiovasc Interv. 2022 Apr 02 |
253 ## - Journal Name |
Journal name |
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2022 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2022 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Publication date |
2022 Apr 02 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
aheadofprint |
266 ## - Date added to catalog |
Date added to catalog |
2022-05-11 |
520 ## - SUMMARY, ETC. |
Abstract |
BACKGROUND: The index of microvascular resistance (IMR) is an established tool to assess the status of coronary microcirculation. However, the need for a pressure wire and hyperemic agents have limited its routine use and have led to the development of angiography-derived pressure-wire-free methods (angiography-derived IMR [IMRAngio]). In this review and meta-analysis, we aim to assess the global diagnosis accuracy of IMRAngio versus IMR. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSION: IMRAngio shows a good diagnostic performance for the prediction of abnormal IMR. Copyright © 2022 Wiley Periodicals LLC. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: A systematic review of the literature was performed. Studies directly evaluating IMRAngio versus IMR were considered eligible. Pooled values of diagnostic test and summary receiver operator curve were calculated. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: Seven studies directly comparing IMRAngio versus IMR were included (687 patients; 807 vessels). Pooled sensitivity, specificity, +likelihood ratio (LR), and -LR were 82%, 83%, 4.5, and 0.26 respectively. Pooled accuracy was 83% while pooled positive predictive value and negative predictive value were 76% and 85%, respectively. Comparable results were obtained when analyzing by clinical scenario (acute and nonacute coronary syndromes). |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
IN PROCESS -- NOT YET INDEXED |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Heart & Vascular Institute |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Garcia-Garcia, Hector M |
790 ## - Authors |
All authors |
De Maria GL, Echavarria-Pinto M, Fernandez-Peregrina E, Garcia-Garcia HM, Kotronias R, Sans-Rosello J, Sanz-Sanchez J, Scarsini R, Tebaldi M |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1002/ccd.30174">https://dx.doi.org/10.1002/ccd.30174</a> |
Public note |
https://dx.doi.org/10.1002/ccd.30174 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |