MARC details
000 -LEADER |
fixed length control field |
03477nam a22003977a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
220316s20222022 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1861-0684 |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1007/s00392-022-01994-4 [doi] |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1007/s00392-022-01994-4 [pii] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
35212802 |
245 ## - TITLE STATEMENT |
Title |
Complex vs. non-complex percutaneous coronary intervention with newer-generation drug-eluting stents: an analysis from the randomized BIOFLOW trials. |
251 ## - Source |
Source |
Clinical Research in Cardiology. 2022 Feb 25 |
252 ## - Abbreviated Source |
Abbreviated source |
Clin. res. cardiol.. 2022 Feb 25 |
253 ## - Journal Name |
Journal name |
Clinical research in cardiology : official journal of the German Cardiac Society |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2022 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2022 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Publication date |
2022 Feb 25 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
aheadofprint |
266 ## - Date added to catalog |
Date added to catalog |
2022-03-17 |
520 ## - SUMMARY, ETC. |
Abstract |
AIM: We sought to compare the clinical outcomes after complex PCI with a bioresorbable-polymer sirolimus-eluting stent (BP-SES) versus a durable-polymer everolimus-eluting stent (DP-EES). |
520 ## - SUMMARY, ETC. |
Abstract |
BACKGROUND: Patients undergoing complex percutaneous coronary intervention (PCI) are at higher risk of adverse outcomes, but data are scarce in the era of newer-generation coronary stents. |
520 ## - SUMMARY, ETC. |
Abstract |
CLINICAL TRIAL REGISTRATION: Clinicaltrial.gov NCT01356888, NCT01939249, NCT02389946, https://clinicaltrials.gov/show/NCT01356888 ; https://clinicaltrials.gov/show/NCT01939249 ; https://clinicaltrials.gov/show/NCT02389946 . Copyright © 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSION: Patients undergoing complex PCI with the newer-generation DES still sustain a higher risk of TLF, TV-MI and stent thrombosis as compared with non-complex PCI. This adverse outcome was not significantly modified by the stent platform (BP-SES vs. DP-EES). |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: Patients (n = 2350) from BIOFLOW-II, -IV, and -V randomized trials were categorized into non-complex PCI vs. complex PCI. Complex PCI had at least one of the following criteria: multi-vessel PCI, >= 3 lesions treated, >= 3 stents implanted, total stent length >= 60 mm. Endpoints were target lesion failure (TLF: cardiac death, target-vessel myocardial infarction [TV-MI], or target lesion revascularization [TLR]) and probable/definite stent thrombosis (ST) at three years. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: Patients with complex PCI (n = 348) were older and presented more often with acute coronary syndrome than non-complex PCI patients (n = 2002). Complex PCI lesions were more often type B2/C and bifurcation lesions and required more pre- and post-dilatation. Complex PCI patients had higher rates of TLF (14.6% vs. 8.1%; aHR 1.89, 95% CI [1.31-2.73], p = 0.001), TV-MI (10.2% vs. 4.4%, aHR 2.17, 95% CI [1.40-3.37], p = 0.001), and ST (1.5% vs. 0.4%, p = 0.025) as compared with non-complex PCI. TLF was not lower with BP-SES as compared to DP-EES in complex PCI (12.6% vs 18.2%, p = 0.16). |
546 ## - LANGUAGE NOTE |
Language note |
English |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Heart & Vascular Institute |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Heart & Vascular Instituteon |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Garcia-Garcia, Hector M |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Waksman, Ron |
790 ## - Authors |
All authors |
Abdelghani M, Allali A, Elbasha K, Farhan S, Garcia-Garcia HM, Hemetsberger R, Kandzari D, Lefevre T, Mankerious N, Richardt G, Saito S, Toelg R, Waksman R, Windecker S |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1007/s00392-022-01994-4">https://dx.doi.org/10.1007/s00392-022-01994-4</a> |
Public note |
https://dx.doi.org/10.1007/s00392-022-01994-4 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |