Impact of Significant Hemoglobin Drop Without Bleeding in Patients Undergoing Transcatheter Aortic Valve Replacement.
Publication details: 2024; ; ISSN:- 2047-9980
- *Aortic Valve Stenosis
- *Hemoglobins
- *Hospital Mortality
- *Transcatheter Aortic Valve Replacement
- Aged
- Aged, 80 and over
- Aortic Valve Stenosis/mo [Mortality]
- Aortic Valve Stenosis/su [Surgery]
- Female
- Hemoglobins/an [Analysis]
- Hemoglobins/me [Metabolism]
- Humans
- Male
- Retrospective Studies
- Risk Assessment/mt [Methods]
- Risk Factors
- Transcatheter Aortic Valve Replacement/ae [Adverse Effects]
- Transcatheter Aortic Valve Replacement/mo [Mortality]
- Treatment Outcome
- -- Curated
- MedStar Heart & Vascular Institute
- MedStar Washington Hospital Center
- Advanced Cardiac Catheterization Research Fellowship
- Journal Article
Item type | Current library | Collection | Call number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|---|
Journal Article | MedStar Authors Catalog | Article | Available | 38818933 |
BACKGROUND: Hemoglobin (Hgb) drop without bleeding is common among patients undergoing transcatheter aortic valve replacement; however, the clinical implications of significant Hgb drop have not been fully evaluated.
CONCLUSIONS: Hgb drop without bleeding is common among patients undergoing transcatheter aortic valve replacement and may represent a higher risk of periprocedural death. Blood transfusion increases short- and midterm mortality risk in patients with and without bleeding, supporting a restrictive transfusion strategy.
METHODS AND RESULTS: Consecutive patients undergoing transcatheter aortic valve replacement at our institution from 2011 to 2021 were retrospectively reviewed. Three groups were assessed: no Hgb drop and no bleed (NoD-NoB [reference group]), Hgb drop with bleed, and Hgb drop and no bleed (D-NoB). Hgb drop was defined as >=3 g/dL decrease from pre- to post-transcatheter aortic valve replacement. Outcomes of interest were in-hospital death and 1-year all-cause mortality. A total of 1851 cases with complete Hgb data were included: NoD-NoB: n=1579 (85.3%); D-NoB: n=49 (2.6%); Hgb drop with bleed: n=223 (12.6%). Compared with NoD-NoB, the D-NoB group was older (81.1 versus 78.9 years of age) with higher preprocedure Hgb (12.9 versus 11.7 g/dL). In-hospital death rate was higher among patients with D-NoB versus NoD-NoB (4.5% versus 0.8%, P<0.001) and similar to Hgb drop with bleed (4.5% versus 4.1%, P=0.999). Predictors of in-hospital death were D-NoB (odds ratio [OR], 3.45 [95% CI, 1.32-8.69]) and transfusion (OR, 10.6 [95% CI, 4.25-28.2]). Landmark survival analysis found that D-NoB experienced 1-year mortality rate comparable to NoD-NoB, whereas Hgb drop with bleed had higher midterm mortality (hazard ratio [HR], 3.2 [95% CI, 1.83-5.73]), and transfusion continued to impact mortality (HR, 2.5 [95% CI, 1.79-3.63]).
English