Impact of intravascular ultrasound on Outcomes following PErcutaneous coronary interventioN for In-stent Restenosis (iOPEN-ISR study).
Citation: International Journal of Cardiology. 340:17-21, 2021 Oct 01.PMID: 34371029Institution: MedStar Heart & Vascular InstituteForm of publication: Journal ArticleMedline article type(s): Journal ArticleSubject headings: *Coronary Artery Disease | *Coronary Restenosis | *Drug-Eluting Stents | *Percutaneous Coronary Intervention | Coronary Angiography | Coronary Restenosis/dg [Diagnostic Imaging] | Coronary Restenosis/et [Etiology] | Humans | Percutaneous Coronary Intervention/ae [Adverse Effects] | Treatment Outcome | Ultrasonography, InterventionalYear: 2021ISSN:- 0167-5273
Item type | Current library | Collection | Call number | Status | Date due | Barcode |
---|---|---|---|---|---|---|
Journal Article | MedStar Authors Catalog | Article | 34371029 | Available | 34371029 |
BACKGROUND: Percutaneous coronary intervention (PCI) for in-stent restenosis (ISR) remains common. Intravascular imaging allows for the determination of the mechanism of ISR, potentially guiding appropriate therapy. Intravascular ultrasound (IVUS)-guided stent implantation is associated with a reduction in adverse events after PCI, but its impact on treatment of ISR is not clear.
CONCLUSIONS: The use of IVUS is associated with decreased MACE at 1 year following PCI for ISR. These results support routine IVUS for the treatment of ISR lesions. Copyright (c) 2021. Published by Elsevier B.V.
METHODS: All patients with 1-year follow-up after ISR treatment from 2003 through 2016 were included and stratified by IVUS use. The primary endpoint was the rate of major adverse cardiac events (MACE) at 1 year, defined as the composite of all-cause mortality, Q-wave myocardial infarction, and target vessel revascularization (TVR).
RESULTS: The final analysis included 1522 ISR patients, 65.9% of whom were treated with IVUS guidance. The primary endpoint occurred in 18.0% of patients treated with IVUS guidance vs. 24.5% of patients treated with angiography guidance (p = 0.0014). Post-dilatation was used more often with IVUS (18.6% vs. 14.1%, p < 0.001), with a larger diameter of new stents (3.04 +/- 0.35 mm vs. 2.94 +/- 0.47 mm, p = 0.001). At 1 year, TVR occurred in 14.5% with IVUS guidance and 19.2% with angiography guidance (p = 0.021).
English