MARC details
000 -LEADER |
fixed length control field |
05382nam a22006977a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
201006s20202020 xxu||||| |||| 00| 0 eng d |
022 ## - INTERNATIONAL STANDARD SERIAL NUMBER |
International Standard Serial Number |
1941-3084 |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1161/CIRCEP.120.008503 [doi] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
32915063 |
245 ## - TITLE STATEMENT |
Title |
Cost-Effectiveness of an Antibacterial Envelope for CIED Infection Prevention in the US Healthcare System from the WRAP-IT Trial. |
247 ## - FORMER TITLE |
Title |
Cost-Effectiveness of an Antibacterial Envelope for Cardiac Implantable Electronic Device Infection Prevention in the US Healthcare System From the WRAP-IT Trial. |
251 ## - Source |
Source |
Circulation: Arrhythmia and Electrophysiology. 13(10):e008503, 2020 10. |
252 ## - Abbreviated Source |
Abbreviated source |
Circ. Arrhythm. electrophysiol.. 13(10):e008503, 2020 10. |
252 ## - Abbreviated Source |
Former abbreviated source |
Circ. Arrhythm. electrophysiol.. 2020 Sep 11 |
253 ## - Journal Name |
Journal name |
Circulation. Arrhythmia and electrophysiology |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2020 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2021 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
aheadofprint |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
ppublish |
266 ## - Date added to catalog |
Date added to catalog |
2020-10-06 |
268 ## - Previous citation |
-- |
Circulation: Arrhythmia and Electrophysiology. 2020 Sep 11 |
501 ## - WITH NOTE |
Local holdings |
Available online from MWHC library: 2008 - present |
520 ## - SUMMARY, ETC. |
Abstract |
Background - In the WRAP-IT trial, adjunctive use of an absorbable antibacterial envelope resulted in a 40% reduction of major cardiac implantable electronic device (CIED) infection without increased risk of complication in 6,983 patients undergoing CIED revision, replacement, upgrade, or initial cardiac resynchronization therapy defibrillator (CRT-D) implant. There is limited information on the cost-effectiveness of this strategy. As a pre-specified objective, we evaluated antibacterial envelope cost-effectiveness compared to standard-of-care infection prevention strategies in the US healthcare system. Methods - A decision tree model was used to compare costs and outcomes of antibacterial envelope (TYRX) use adjunctive to standard-of-care infection prevention vs. standard-of-care alone over a lifelong time horizon. The analysis was performed from an integrated payer-provider network perspective. Infection rates, antibacterial envelope effectiveness, infection treatment costs and patterns, infection-related mortality, and utility estimates were obtained from the WRAP-IT trial. Life expectancy and long-term costs associated with device replacement, follow-up, and healthcare utilization were sourced from the literature. Costs and quality-adjusted life years (QALYs) were discounted at 3%. An upper willingness-to-pay (WTP) threshold of |
-- |
50,000 per QALY was used to determine cost-effectiveness, in alignment with American College of Cardiology and American Heart Association (ACC/AHA) practice guidelines and as supported by the World Health Organization (WHO) and contemporary literature. Results - The base-case incremental cost-effectiveness ratio (ICER) of the antibacterial envelope compared to standard-of-care was |
-- |
12,603/QALY. The ICER remained lower than the WTP threshold in 74% of iterations in the probabilistic sensitivity analysis and was most sensitive to the following model inputs: infection-related mortality, life expectancy, and infection cost. Conclusions - The absorbable antibacterial envelope was associated with a cost-effectiveness ratio below contemporary benchmarks in the WRAP-IT patient population, suggesting that the envelope provides value for the US healthcare system by reducing the incidence of CIED infection. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Anti-Bacterial Agents/ec [Economics] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Antibiotic Prophylaxis/ec [Economics] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Cardiac Resynchronization Therapy Devices/ec [Economics] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Defibrillators, Implantable/ec [Economics] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Drug Costs |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Prosthesis Implantation/ec [Economics] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
*Prosthesis-Related Infections/ec [Economics] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Absorbable Implants/ec [Economics] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Anti-Bacterial Agents/tu [Therapeutic Use] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Cardiac Resynchronization Therapy Devices/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Clinical Decision-Making |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Cost Savings |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Cost-Benefit Analysis |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Decision Trees |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Defibrillators, Implantable/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Humans |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Models, Economic |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Multicenter Studies as Topic |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Prosthesis Implantation/ae [Adverse Effects] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Prosthesis Implantation/is [Instrumentation] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Prosthesis-Related Infections/mi [Microbiology] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Prosthesis-Related Infections/pc [Prevention & Control] |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Quality of Life |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Quality-Adjusted Life Years |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Randomized Controlled Trials as Topic |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Risk Factors |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Time Factors |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Treatment Outcome |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
United States |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Heart & Vascular Institute |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Eldadah, Zayd A |
790 ## - Authors |
All authors |
Berman BJ, Boriani G, Collier J, Corey R, Cronin EM, Eldadah Z, Evonich RF, Gallastegui JL, Holbrook RW, Kennergren C, Khan HH, Krahn AD, Lande JD, Lexcen DR, Mittal S, Pickett RA, Poole JE, Riggio DW, Roark SF, Schloss EJ, Seshadri S, Sholevar DP, Silver MT, Sorrentino DM, Tarakji KG, Wilkoff BL |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1161/CIRCEP.120.008503">https://dx.doi.org/10.1161/CIRCEP.120.008503</a> |
Public note |
https://dx.doi.org/10.1161/CIRCEP.120.008503 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |