MARC details
000 -LEADER |
fixed length control field |
02724nam a22003617a 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
210726s20212021 xxu||||| |||| 00| 0 eng d |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
10.1016/j.fas.2021.06.004 [doi] |
024 ## - OTHER STANDARD IDENTIFIER |
Standard number or code |
S1268-7731(21)00134-X [pii] |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
Ovid MEDLINE(R) |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) |
PMID |
34247921 |
245 ## - TITLE STATEMENT |
Title |
Fiber-reinforced fixation implant for proximal interphalangeal joint arthrodesis shows implant bio-integration at 1-year follow-up. |
251 ## - Source |
Source |
Journal of Foot & Ankle Surgery. 2021 Jul 03 |
252 ## - Abbreviated Source |
Abbreviated source |
J Foot Ankle Surg. 2021 Jul 03 |
253 ## - Journal Name |
Journal name |
Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Year |
2021 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Manufacturer |
FY2022 |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Publication date |
2021 Jul 03 |
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE] |
Publication status |
aheadofprint |
266 ## - Date added to catalog |
Date added to catalog |
2021-07-26 |
501 ## - WITH NOTE |
Local holdings |
Available online through MWHC library: 2003 - present, Available in print through MWHC library:1999-2007 |
520 ## - SUMMARY, ETC. |
Abstract |
BACKGROUND: A new bio-integrative fiber-reinforced implant (OSSIOfiber R Hammertoe Fixation Implant, OSSIO Ltd., Caesarea, Israel) was developed for proximal interphalangeal joint (PIPJ) correction-arthrodesis. The main purpose of this clinical study was to assess implant bio-integration at 1-year follow-up. |
520 ## - SUMMARY, ETC. |
Abstract |
CONCLUSIONS: This study demonstrates safe bio-integration of the newly developed fiber-reinforced implant at 1-year follow-up without negative side effects. Copyright (c) 2021. Published by Elsevier Ltd. |
520 ## - SUMMARY, ETC. |
Abstract |
METHODS: Twenty-four patients, previously treated for a Hammertoe deformity using the bio-integrative, fiber-reinforced implant, were enrolled in this follow-up study. One-year follow-up included clinical examination, patient reported outcomes, radiographs, Magnetic Resonance Imaging (MRI) and bio-integration scoring. |
520 ## - SUMMARY, ETC. |
Abstract |
RESULTS: Proximal interphalangeal joint (PIPJ) radiographic fusion rate was 92% (n = 22). MRI was analyzed for 24 (100%) patients. In 100% of patients (n = 24), the border between implant and surrounding tissue was scored as partially visible. There were no cyst formation or fluid accumulation findings. Mild bone edema was detected in 29% (n = 7) and is attributed to the chronic distribution of forces due to chronic abnormal gait and pasture. None of the edema findings were considered as adverse implant-related finding. The mean bio-integration score was 7.71 +/- 0.46. |
546 ## - LANGUAGE NOTE |
Language note |
English |
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
IN PROCESS -- NOT YET INDEXED |
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME |
Institution |
MedStar Union Memorial Hospital |
657 ## - INDEX TERM--FUNCTION |
Medline publication type |
Journal Article |
700 ## - ADDED ENTRY--PERSONAL NAME |
Local Authors |
Miller, Stuart |
790 ## - Authors |
All authors |
Cicchinelli LD, Miller S, Richter M, Stalc J |
856 ## - ELECTRONIC LOCATION AND ACCESS |
DOI |
<a href="https://dx.doi.org/10.1016/j.fas.2021.06.004">https://dx.doi.org/10.1016/j.fas.2021.06.004</a> |
Public note |
https://dx.doi.org/10.1016/j.fas.2021.06.004 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Koha item type |
Journal Article |
Item type description |
Article |