Preclinical safety and electrical performance of novel atrial leadless pacemaker with dual-helix fixation. (Record no. 809)

MARC details
000 -LEADER
fixed length control field 03653nam a22005177a 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 220221s20222022 xxu||||| |||| 00| 0 eng d
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code 10.1016/j.hrthm.2022.01.021 [doi]
024 ## - OTHER STANDARD IDENTIFIER
Standard number or code S1547-5271(22)00036-4 [pii]
040 ## - CATALOGING SOURCE
Original cataloging agency Ovid MEDLINE(R)
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
PMID 35066177
245 ## - TITLE STATEMENT
Title Preclinical safety and electrical performance of novel atrial leadless pacemaker with dual-helix fixation.
251 ## - Source
Source Heart Rhythm. 19(5):776-781, 2022 May.
252 ## - Abbreviated Source
Abbreviated source Heart Rhythm. 19(5):776-781, 2022 May.
252 ## - Abbreviated Source
Former abbreviated source Heart Rhythm. 2022 Jan 20
253 ## - Journal Name
Journal name Heart rhythm
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Year 2022
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Manufacturer FY2022
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Publication date 2022 Jan 20
265 ## - SOURCE FOR ACQUISITION/SUBSCRIPTION ADDRESS [OBSOLETE]
Publication status ppublish
266 ## - Date added to catalog
Date added to catalog 2022-02-21
268 ## - Previous citation
-- Heart Rhythm. 2022 Jan 20
501 ## - WITH NOTE
Local holdings Available online through MWHC library: 2004 - present
520 ## - SUMMARY, ETC.
Abstract BACKGROUND: Complications associated with transvenous pacemakers, specifically those involving the lead or subcutaneous pocket, may be avoided with leadless pacemakers (LPs). The safety and efficacy of single-chamber right ventricular LPs have been demonstrated, but their right atrium (RA) use poses new design constraints.
520 ## - SUMMARY, ETC.
Abstract CONCLUSION: The novel atrial LP demonstrated successful implantation, with acceptable electrical performance, mechanical stability, and safety in a 12-week preclinical study. Copyright (c) 2022 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
520 ## - SUMMARY, ETC.
Abstract METHODS: A new LP was designed with a dual-helix fixation mechanism specific to the RA anatomy. A 12-week preclinical ovine study was conducted to evaluate implant success, electrical performance, mechanical stability, and safety in vivo, with supporting benchtop measurements to quantify the mechanical forces needed for device retrieval and dislodgment.
520 ## - SUMMARY, ETC.
Abstract OBJECTIVES: The purpose of this study was to evaluate the implant success, electrical performance, and safety of a novel RA LP design in benchtop and preclinical studies.
520 ## - SUMMARY, ETC.
Abstract RESULTS: LPs were successfully implanted in all 10 ovine subjects with no complications. The pacing capture threshold improved significantly over time from implant to week 12 (1.1 +/- 0.7 V vs 0.4 +/- 0.2 V, P = .008). Sensing amplitudes and pacing impedances were stable from implant to week 12 (4.8 +/- 1.8 mV vs 6.0 +/- 1.9 mV, P = .160; and 393 +/- 77 OMEGA vs 398 +/- 65 OMEGA, P = .922, respectively). Gross pathology and microscopic histology revealed no adverse interactions and no evidence of device dislodgment or clinically significant myocardial perforation. Benchtop ex vivo porcine atrial tissue measurements revealed greater pull forces required to dislodge the LP vs transvenous active fixation lead (0.42 +/- 0.18 lbf vs 0.29 +/- 0.08 lbf, P = .020), and greater rotational forces required for deliberate extraction (0.28 +/- 0.04 lbf vs 0.14 +/- 0.07 lbf, P <.001).
546 ## - LANGUAGE NOTE
Language note English
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Lipopolysaccharides
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element *Pacemaker, Artificial
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Animals
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Cardiac Pacing, Artificial
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Equipment Design
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Heart Atria
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Humans
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Prostheses and Implants
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Sheep
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Swine
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Treatment Outcome
651 ## - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME
Institution MedStar Heart & Vascular Institute
657 ## - INDEX TERM--FUNCTION
Medline publication type Journal Article
700 ## - ADDED ENTRY--PERSONAL NAME
Local Authors Eldadah, Zayd A
790 ## - Authors
All authors Badie N, Banker RS, Breeman K, Cantillon DJ, Doshi R, Eldadah Z, Knops RE, Ligon D, Nee P, Neuzil P, Rashtian M, Rippy MK, Victorine K
856 ## - ELECTRONIC LOCATION AND ACCESS
DOI <a href="https://dx.doi.org/10.1016/j.hrthm.2022.01.021">https://dx.doi.org/10.1016/j.hrthm.2022.01.021</a>
Public note https://dx.doi.org/10.1016/j.hrthm.2022.01.021
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Item type description Article
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection Home library Current library Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
          MedStar Authors Catalog MedStar Authors Catalog 02/21/2022   35066177 35066177 02/21/2022 02/21/2022 Journal Article

Powered by Koha